Fluke 393 FC

Product name

Product overview: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

What's in the box:

  • Fluke ii900 Industrial Acoustic Imager
  • AC power supply and battery pack charger (including universal AC adapters)
  • Two rugged lithium ion smart battery packs
  • USB cable
  • Rugged, hard carrying case
  • Adjustable hand strap and neck strap

Specifications: Fluke 393 FC Solar Clamp Meter CAT III 1500 V

Specifications:   
General   
Maximum voltage between any Terminal and Earth Ground  
AC1000 V  
DC1500 V  
Batteries2 AA IEC LR6 alkaline  
DisplayDual display with backlight  
Automatic Power Off20 minutes  
Electrical   
Accuracy   
Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature CoefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC Current: Jaw   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % + 5 digits (10 Hz to 100 Hz) 
 2.5 % + 5 digits (100 Hz to 500 Hz) 
Crest Factor (50/60 Hz)2.5 @600.0 A  
 3.0 @500.0 A  
 1.42 @999.9 A  
 Add 2 % for C.F. >2  
AC Current: Flexible Current Probe   
Range999.9 A  
 2500 A  
Resolution0.1 A (≤999.9 A)  
 1 A (≤2500 A)  
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz) 
Crest Factor (50/60Hz)2.5 @1400 A  
 3.0 @1100 A  
 1.42@2500 A  
 Add 2 % for C.F. >2  
Position Sensitivity   
NEC symbol
Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)±0.5 %
B0.8 in (20.3 mm)2.0 in (50.8 mm)±1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm)±2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
    
DC Current   
Range999.9 A  
Resolution0.1 A  
Accuracy2 % RD + 5 digits[1]  
 [1] When using the ZERO (B) function to compensate for offsets.
AC Voltage   
Range600.0 V  
 1000 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1000 V)  
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz) 
DC Voltage   
Range600.0 V  
 1500 V  
Resolution0.1 V (≤600.0 V)  
 1 V (≤1500 V)  
Accuracy1 % RD + 5 digits  
mV dc   
Range500.0 mV  
Resolution0.1 mV  
Accuracy1 % RD + 5 digits  
Amps Frequency: Jaw   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 10 Hz, ≥10 A  
 10 Hz to 100 Hz, ≥5 A  
 100 Hz to 500 Hz, ≥10 A  
Amps Frequency: Flexible Current Probe   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥25 A  
 20 Hz to 100 Hz, ≥20 A  
 100 Hz to 500 Hz, ≥25 A  
Voltage Frequency   
Range5.0 Hz to 500.0 Hz  
Resolution0.1 Hz  
Accuracy0.5 % RD + 5 digits  
Trigger Level5 Hz to 20 Hz, ≥5 V  
 20 Hz to 100 Hz, ≥5 V  
 100 Hz to 500 Hz, ≥10 V  
DC Power   
Range600.0 kVA (600.0 V dc range)  
 1500 kVA (1500 V dc range)  
Resolution0.1 kVA  
 1 kVA  
Accuracy2 % RD + 2.0 kVA  
 2 % RD + 20 kVA  
Resistance   
Range600.0 Ω  
 6000 Ω  
 60.00 kΩ  
Resolution0.1 Ω (≤600.0 Ω)  
 1 Ω (≤6000 Ω)  
 0.01 kΩ (≤60.00 kΩ)  
Accuracy1 % RD + 5 digits  
Capacitance   
Range100.0 μF  
 1000 μF  
Resolution0.1 μF (≤100.0 μF)  
 1 μF (≤1000 μF)  
Accuracy1 % RD + 5 digits  
Inrush Trigger Level5 A  
Mechanical   
Size (L x W x H)281 mm x 84 mm x 49 mm  
Weight (with batteries)520 g  
Jaw Opening34 mm  
Flexible Current Probe Diameter7.5 mm  
Flexible Current Probe Cable Length   
(head to electronics connector)1.8 m  
Environmental   
Operating Temperature-10 °C to 50 °C  
Storage Temperature-40 °C to 60 °C  
Operating HumidityNon condensing (<10°C)  
 ≤90 % RH (at 10 °C to 30 °C)  
 ≤75 % RH (at 30 °C to 40 °C)  
 ≤45 % RH (at 40 °C to 50 °C)  
Operating Altitude2000 m  
Storage Altitude12 000 m  
Ingress Protection (IP) RatingIEC 60529: IP54 non-operating  
Electromagnetic Compatibility (EMC)   
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
 Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast & Communications Equipment)
 Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety   
GeneralIEC 61010-1, Pollution Degree 2 
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V 
 IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V 
Wireless Radio   
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE 
Wireless Radio Frequency Range2400 MHz to 2483.5 MHz  
Output Power<100 mW  
SIMPLIFIED EU DECLARATION OF CONFORMITY  
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address:  
www.fluke.com/en-us/declaration-of-conformity