The BITE5 will test lead acid batteries, NiCD batteries as well as lithium-ion batteries. It will measure and record battery voltage, impedance, and temperature. The recorded data can be trended on the unit’s touch screen. View the trended data of each test or trend the data of each cell. Set pass, warning, and fail limits for voltage and impedance. Record the ripple voltage, ripple current, and float current and transfer the recorded data via USB or via an SD card to the Power DB software, then create custom reports and automated analysis.
The MGFL100 battery ground fault locator locates ground faults on ungrounded DC and AC systems, DC battery systems, and protected IT networks. It also alarms when the real fault is found, while automatically distinguishing between real fault current and reactive current drawn by stray system capacitance.