Specifications: Fluke FEV300 EV Charging Station Test Adapter
| General features | |
| Input voltage | Up to 250 V (single phase system) / up to 480 V (three phase system), 50/60 Hz, max 10 A |
| Internal power consumption | 3 W max. |
| FEV300-CON-TY2 Plug | AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed cable with vehicle connector (type 2, 7P three-phase) |
| FEV300-CON-TY1 Plug | AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase) |
| Dimensions (H × W × D) | 110 × 45 × 220 mm length without connection cable and test cable |
| Weight (including type 1 or type 2 connection cable) | Approx. 1 kg |
| Safety standards | IEC/EN 61010-1, pollution degree 2 IEC/EN 61010-2-030, CAT II 300 V, protection class II |
| Ingress protection | IEC 60529: IP54 (housing) IEC 60529: IP54 (sockets with protection caps in place, connectors in connected condition or with protection caps in place, otherwise IP20) |
| Operating temperature | -20 °C to 40 °C |
| Storage temperature | -20 °C to 50 °C |
| Operating humidity range | 10 % to 85 % relative humidity non-condensing |
| Storage relative humidity | 0 % to 85 % non-condensing |
| Operating altitude | 2000 m max. |
| Functions | |
| PE Pre-Test | Visible indication >50 V AC/DC between PE conductor and touch sensor |
| PP Simulation | Open, 13 A, 20 A, 32 A, 63 A |
| CP States | State A, B, C, D |
| CP Error state “E” | On/off (CP signal short-circuited to PE) |
| PE Error state "F" (Earth fault) | On/off (interruption of PE conductor) |
| Outputs (for test purpose only) | |
| Measuring terminals L1, L2, L3, N, PE | Max. 250/480 V, max. 10 A |
| CP signal output terminals | Approx. +/-12 V |
| Caution: In case of wrong wiring or error of the charging station these terminals may be hazardous. | |