Fluke TC01A/TC01B

Product name

Product overview: Fluke iSee™ Mobile Thermal Camera - TC01A/TC01B

What's in the box:

  • 256 x 192 pixels, detailed image quality
  • Up to 550 ℃, suitable to use in many applications
  • ±2% or ±2 °C accuracy to ensure reliable results
  • 25Hz frame rate for smooth video recording
  • Customize image view with more than 10 standard or custom color palettes

Specifications: Fluke iSee™ Mobile Thermal Camera - TC01A/TC01B

 TC01ATC01B
Performance specifications
IR resolution256 x 192
Pixel size12 μm
Temperature range-10 ℃ to 550 ℃-20 ℃ to 550 ℃
Temperature accuracy± 2% of rdg or ± 2 °C, whichever is greater (@ 23 °C ± 5 °C ambient temperature)
Temperature measurement distance0.25 to 5 m(* -20 ℃ to 10 ℃, only for 0.25 to 3 m)
Frame rate25 Hz
Warm-up time1 minute
Focal lengthFixed focal length: 3.2 mm
Shutter modeBuilt-in automatic shutter
Thermal sensitivity (NETD)50 mK
Spectral range8 to 14 μm
Field of view (H x V)56° x 42°
Spatial resolution3.81 mrad
General Specifications
USB InterfaceType CLightning
Operating temperature0℃ to 40 ℃
Storage temperature-30 °C to 60 °C
Operating humidity10% to 90% RH, non-condensing
Power consumption350 mW (Typical)200 mW (Typical)
Drop test1 m
Ingress protectionIEC 60529: IP54 (with Type C cover)IEC 60529: IP56
Operating altitude2000 m
Storage altitude12000 m
Dimensions (L x W x H)60 x 33.5 x 11.2 mm
Weight22 g
EMCInternational IEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a lowvoltage power supply network that supplies buildings used for domestic purposes.
There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC) Class A equipment (Industrial Broadcast & Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Warranty2 years