| Specifications |
| Bandwidth | 60 MHz |
| Number of channels | 60 MHz: 2 channels |
| Real-time sample rate | 625 MS/s |
| Inputs | 2 scope plus DMM input |
| Independently floating isolated inputs | Up to 1000 V CAT III/600 V CAT IV between inputs, references and ground |
| Timebase range | 10 ns - 2 min/div |
| Input sensitivity | 2 mV-100 V/div |
| Trigger types | Connect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle |
| Trigger source | Any scope input channel, or external via DMM input |
| Glitch capture | 8 ns |
| Scope measurements | Cursor: 7 |
| Automatic: 30 |
| Maximum record length | ScopeRecord mode: 30,000 pts |
| Scope mode: 10,000 pts per input |
| Persistence | Digital persistence giving analog oscilloscope-like waveform decay |
| Waveform compare | Waveform reference with automatic Pass/Fail testing |
| DMM Specification |
| Meter inputs (also used as External Trigger Input for the Oscilloscope Mode) | 4 mm banana inputs, fully isolated from scope inputs and from scope ground |
| Maximum resolution | 5000 counts |
| Measurements | VDC, VAC rms, VAC + DC rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature °C or °F (using optional converter) |
| Memory | Screen + Setup: 30 |
| Recording: 10 |
| Display | 153 mm full color LCD with fast update rate |
| Environmental Specifications |
| Operating temperature | 0 °C to 40 °C Including Batteries |
| 0 °C to 50 °C Excluding Batteries |
| Storage temperature | -20 °C to +60 °C |
| Operating altitude | Up to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V |
| Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V |
| Safety Specifications |
| Electrical safety | 1,000V CAT III/600V CAT IV (EN61010-1) |
| Mechanical and General Specifications |
| Size | 270 x 190 x 70 mm |
| Weight | 2.2 kg |
| Warranty | 3-years on main instrument, 1-year on accessories |
| Li-Ion battery | BP290 2400 mAh battery up to 4 hours included standard |
| Included Accessories |
| Two channel models | VPS410 Voltage Probe Sets (one red, one blue) |
| TL175 TwistGuard™ safety designed Test Lead Set (red and black) |
| BC190 Battery Charger/mains Adapter |
| BP290 2400 mAh Li-ion Battery |
| Handstrap (affixed to instrument) |
| Hangstrap |
| Multi-Language User Manuals on CD-Rom |
| FlukeView ScopeMeter® demo package (restricted functionality) |
| USB Interface Cable |
| Warranty | Three years on main instrument, one year on accessories |