Specifications: Fluke FLK-IRR1-SOL Solar Irradiance Meter

Irradiance
Measuring Range100 to 1400 W/m²
Resolution1 W/m²
Measuring Accuracy± (5 % + 5 Digit)
Note: Irradiance measurement accuracy is specified for an angle of incidence ≤35 degrees from the sun at AM1.5 (ASTM G-173) spectrum.
Temperature Measurement
Measuring range (°C)-30 °C to 100 °C (-22 °F to 212 °F)
Resolution0.1 °C (0.2 °F) / 1 °F @>100 °F
Measuring Accuracy"±5 °C (±9 °F)@ -10 °C to 75 °C (14 °F to 167 °F),
±8 °C (±14.5 °F)@ -30 °C to -10 °C (-22 °F to 14 °F), and
75 °C to 100 °C (167 °F to 212 °F)"
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring Range-90° to +90°
Resolution0.1°
Measuring Accuracy (typical)± 1.5°@ -50° to +50°
±2.5° @ -85° to -50° and +50° to +85°
±3.5° @ -90° to -85° and +85° to +90°
Compass
Measuring Range0° to 360°
Resolution
Measuring Accuracy±7°
Note:
a) Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range on LCD will be shown "---".
b) Result is referred to magnetic north.
Temperature
Operating Temperature IRR1-SOL-20 °C to 50 °C (humidity <80%), noncondensing
Operating Temperature 80PR-IRR-30 °C to +100 °C
Storage Temperature-30 °C to 60 °C (humidity <80%)
Altitude0 m to max. 2000 m
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Protection
IP ProtectionIP40
Power Supply & Battery Life
Batteries4 AA Alkaline Batteries
Battery Life (typical)50 hours (≤9000 readings)
Auto Power Off30 minutes
Dimensions
L x W x H150 x 80 x 35 mm (5.90 x 3.14 x 1.37 in)
Weight231 g (0.5 lb)