Fluke 83 V Digital Multimeter

Product name

Product overview: Fluke 83V Average Responding Industrial Multimeter

What's in the box:

  • Fluke 83 V Digital Multimeter
  • (1 pair) TL75 Test Leads
  • (1 pair) AC175 Alligator Clips
  • Holster
  • 9V Battery (Installed)
  • Quick reference guide

Specifications: Fluke 83V Average Responding Industrial Multimeter

Specifications
Voltage DCMaximum voltage1000 V
Accuracy±(0.1% + 1)
Maximum resolution100 µV
Voltage ACMaximum voltage1000 V
Accuracy±(0.5% + 2)
Maximum resolution0.1 mV
Current DCMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(0.4% + 2)
Maximum resolution0.01 mA
Current ACMaximum amps10 A (20 A for 30 seconds maximum)
Amps accuracy±(1.2% + 2)
Maximum resolution0.1 µA
ResistanceMaximum resistance50 MΩ
Accuracy±(0.4% + 1)
Maximum resolution0.1 Ω
CapacitanceMaximum capacitance9,999 µF
Accuracy±(1% + 2)
Maximum resolution0.01 nF
FrequencyMaximum frequency200 kHz
Accuracy±(0.005% + 1)
Maximum resolution0.01 Hz
Duty cycleMaximum duty cycle99.9%
Accuracy±(0.2% per khz + 0.1%)
Maximum resolution0.1%
ConductanceMaximum conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty cycle rangeAccuracywithin ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature–20°C to +55°C
Storage temperature–40°C to +60°C
Humidity (without condensation)0% – 90% (0°C – 35°C)
0% – 70% (35°C – 55°C)
Operating altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvalsCSA, TÜV
Mechanical and General Specifications
DisplayDigital6000 counts updates 4/sec
Analog32 segments, updates 40/sec
Frequency19,999 counts, updates 3/sec at > 10 Hz
Size201 x 98 x 52 mm (with holster)
Weight355 g
Weigh with holster and flex–stand624 g
WarrantyLifetime
Battery lifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010–1:2001
VibrationPer MIL–PRF–28800 for a Class 2 instrument